In 2009, I bought an Iolair MB24W, one of those with a MVA display. Except the time when I had to reset the screen to restore the EDID (Press M, +, - until the blue LED blinks 3 times), the screen works fine … until recently.

The screen switches on but stays white. No picture at all, not even the OSD menu.

Let’s look inside. Maybe it’s a disconnected cable like most forums will suggest.

Rear of the opened Iolair MB24W monitor with the back cover removed

Until now, it looks good. Let’s look at the electronic board.

The electronic board of the Iolair MB24W taken out of the case

Found it !! Three capacitors are dead. (The 3 purple ones). It’s noticeable by the little dark liquid that escaped from the safety valve.

Either I replace the entire board, EMAX PWR1002406003, that costs ~40€ online or try to replace the 3 capacitors rated 1200µF 16V.

Three bulging purple electrolytic capacitors on the power board, with leaked electrolyte

3€ later, the capacitors are changed and the screen is working again perfectly fine 🙂