You can buy a Segger JTAG J-Link clone for a few USD on ebay, aliexpress, dx, …
If you try to update its firmware with the official Segger tool, you’ll brick the probe.
Don’t worry, smart people have already put a checklist to restore a working firmware and even update it to the latest official version. I just put all the needed info into one single page.
Unbrick it
To restore the firmware, you need to follow the instructions from http://www.sonsivri.to/forum/index.php?topic=41726.50. The best part? It works from Linux.
For the step 9, you’ll need the binary image to flash; use that one V8_Firmware_NoSerial_(crackn). It’s from the same forum as above but without a password and without additional useless .exe files.
- Download and install SAM-BA package from atmel.com (http://www.atmel.com/tools/ATMELSAM-BAIN-SYSTEMPROGRAMMER.aspx)
- Open the j-link case by gently popping the plastic edge near the JTAG or USB ports.
- Identify the ERASE (pin 50) / TST (pin 40) jumpers/pins
- Short ERASE jumper to pull-high and connect the jlink to USB; wait for a minute and disconnect USB. (“pull-high”, means set a jumper between the ERASE pin and the 3.3V pin next to it.)
- Remove the ERASE jumper and short the TST jumper to pull-high and connect the jlink to USB; wait for a minute and disconnect USB.
- Break/remove the TST jumper and reconnect USB
- Your jlink should now be identified as AT91 USB to serial adapter and a COM port should be assigned to it - if this doesn’t happen repeat from step 3.
Something likecdc_acm 1-1.2:1.0: ttyACM0: USB ACM deviceshould appear in syslog or dmesg - Open SAM-BA program; select COM/ttyACM port that was assigned to your jlink and in board select “at91sam7s64-ek”; click CONNECT
- Select “FLASH” and select the BIN file you downloaded before and select to load the firmware into flash; the application will ask you if you want to unlock - select YES; at the end of programming there will be a similar question if you want to lock - select NO! (very important)
- Congratulations, you are done. Reconnect the device and you should have a working jlink
Update the firmware
The previous step will reflash with a firmware from 2009.Info : J-Link ARM V8 compiled May 27 2009 17:31:22
Quite old and I prefer to have the latest one.
Fortunately, the firmware you just flashed has a fake SerialNumber set to -1 and it happens to be enough to let the J-Link Configurator tool flash it to the latest firmware without bricking it. This time you’ll need a Windows machine. I used a Windows 10 image under VMware and it worked fine.
- go to https://www.segger.com/jlink-software.html and fetch the Windows software pack. The one I used was version 5.00g.
- install it and run the J-Link Configurator.
- It should detect the probe and allow you to update it to the latest firmware

- Congratulations, you are done. Reconnect the device and you should have a working J-Link with the latest firmware
Info : J-Link ARM V8 compiled Nov 28 2014 13:44:46
Edit1
While the origin of the binary firmware used in this tutorial remains unknown, several posts suggest modifying the ‘GDBFull’ string to either ‘GDBFULL’ or ‘GDB’
From http://www.sonsivri.to/forum/index.php?topic=41726.msg143919#msg143919:
<em>After found the BIN file, you have to open it with an hex editor and change the string "GDBFull" with "GDB" and also change the serial number. As far as I remember the serial number is not a string but just raw hex data nearby the address where the "GDBFull" string is located. Remember the raw data are little-endian. For the new serial number use something like "4054xxxx" where xxxx are random numbers.</em>

4 linkbacks (pingbacks from WordPress)